Selection of electric control valve for vortex air pump

source:Industry News release time:2021-07-29 Article author:Rosit Popular:Air band saw

  Nowadays, more and more industries are used in vortex air pumps, especially some industries with high requirements for flow rate and opening height. Generally, certain electric control valves are selected. Electric control valves can be adjusted according to the needs of the working environment of each industry. And make relevant adjustments.

 Water pump

  The main control parameters of the electric control valve are: nominal diameter, design nominal pressure, allowable temperature range of medium, flow coefficient, etc. However, the key to the quality of the electric control valve depends on the sealing performance of the electric control valve. However, the sealing performance of the valve is mainly divided into two aspects, one is internal leakage and external leakage, so you must pay attention to the sealing performance when choosing an electric control valve. When choosing an electric control valve, environmental protection, energy saving, easy installation and maintenance should also be considered, which can bring great convenience to the subsequent work.

  In addition, if vibration occurs during the operation of the fan, it can be eliminated from the following aspects:

  1. The pressure of the vortex air pump is high. a. The vortex air pump is selected incorrectly (the air volume is too small). b. The pipe is blocked. Disassemble the air outlet of the vortex pump, clean up the dirt in the pipe, and check whether the aeration head is blocked. If it is blocked, replace it. c. If the air chamber (oil and gas separation tank) is blocked, please disassemble the air outlet (open) of the vortex air pump and test the machine. If the pressure of the vortex air pump does not drop to 0MPA, there is a blockage fault in the air chamber, and the air chamber needs to be disassembled and checked. Check the pipeline.

  2. The vortex air pump or motor bearing is damaged, disassemble the vortex air pump or replace the motor.

  3. Damage to the inside of the vortex air pump, a. The inside of the vortex air pump may enter stolen goods.

  4. The vortex air pump is rusty in the water, disassemble the machine for repair.

  5. The vortex air pump room has a poor sound-absorbing design.


Read recommendations:

CN22-6075 Nut Cutter丨Split-type Nut Cutter

AN71-2000 Torque Multiplier

Tool Bits

Abrasive Blades

Precautions in the process of high-voltage electric disassembly

Previous:The purpose of the vortex pump determines which model Next:Selection of the control valve of the vortex air pump

related articles

Using Chainsaws to Cut Snow?

2024-05-21

What to do if the pneumatic wrench is weak

2022-12-19

Hydraulic chain saw

2022-12-13

Operation of the wrench

2022-12-06

Introduction to the principle of pneumatic wrench

2022-11-28

How to use the pneumatic wrench

2022-11-21

Brief introduction to the principle of pneumatic wrench

2022-11-14

Impact pneumatic wrench

2022-11-07

Correct hydraulic wrench operation procedure

2022-11-01

Hydraulic wrench torque pressure conversion

2022-11-01

Field operation procedure of hydraulic wrench

2022-10-24

Hydraulic radial plunger motor

2022-10-17

The history of hydraulic motors

2022-10-17

Principle of balance hydraulic wrench

2022-10-10

The Price Factor of Smart Electric Torque Wrench

2022-10-10

Introduction to the advantages of using intelligent electric torque wrench

2022-10-10

The Price Factor of Smart Electric Torque Wrench

2022-10-10

Classification and use of wrenches

2022-10-10

hydraulic wrench pressure conversion

2022-10-10

Introduction to the advantages of the use of intelligent electric torque wrench

2022-10-10

Smart Electric Torque Wrench Selection Guide

2022-10-10

Intelligent electric torque wrench for wind power generation

2022-10-09

Uses of open-end wrenches.Pneumatic chainsaw

2022-10-08

What are the driving parts of a hydraulic wrench and what they do

2022-09-30

What are the driving parts of a hydraulic wrench and what they do

2022-09-23

the commonly used wrenches

2022-09-22

Introduction of several common wrenches

2022-09-21

Application scope and daily maintenance method of hydraulic bolt tensioner

2022-09-20

Characteristics of hollow hydraulic wrench and precautions for use

2022-09-19

Characteristics and precautions of driving hydraulic wrench

2022-09-17

Power Tools

CN21-1424 Nut Cutter丨Manual Integrated Nut Cutter

2022-12-12

CN22-5060 Nut Cutter丨Split-type Nut Cutter

2022-12-12

AN71-10000 Torque Multiplier

2023-06-29

LW21-015 Pneumatic Winch

2023-06-29

DC31-150 Hydraulic Core Drill

2023-01-03

AW21-600 Pneumatic Impact Wrench (Ex-proof Series)

2021-06-02

DB21-018 Pneumatic Rotary Drill Heavy Duty

2020-06-13

CC21-530 Pneumatic Light Chainsaw (3.0 kw Series)

2023-06-14

CB22-200 Pneumatic Band Saw - Stainless Steel Series

2023-06-16

AW21-6000 Pneumatic Impact Wrench (Ex-proof Series)

2022-12-19

GG21-125 Pneumatic Angel Grinder

2021-06-15

OF11-060 Pneumatic Fan (light/medium)

2022-12-29

CN22-1924 Nut Cutter丨Split-type Nut Cutter

2023-06-17

CF21-020 Pneumatic Cutter

2022-12-12

DP61-110 Emulsion Two Hand Operation Drill

2022-12-14

AW21-2200 Pneumatic Impact Wrench (Ex-proof Series)

2021-06-15

CB31-120 Hydraulic Band Saw

2020-06-13

CB61-260丨Emulsion Band Saw

2023-06-17

AN51-600 Charging CNC Torque Wrench

2022-12-27

AK21-110 Pneumatic C-Hog Ring Plier (1.5 coil)

2023-06-29

AK51-080 Pneumatic C-Hog Ring Plier (Charging/Manual 1.5 coil)

2023-06-29

CS21-085 Pneumatic Handheld Circular Saw

2021-06-08

OF23-520 Pneumatic Fan (light/medium)

2022-12-29

DA21-032 Pneumatic Angle Drill

2023-06-19

AN11-4500 Electric servo CNC Torque Wrench

2023-06-27

OF27-270 Heavy Fixed Fan

2023-06-28

DL21-005 Pneumatic Pistol Hammer Drill

2020-11-24

CD31-630 Hydraulic Concrete Chainsaw

2023-06-16

DA21-075 Pneumatic Angle Drill

2023-06-19

CD22-380 Pneumatic Concrete Chainsaw (5.0KW)

2023-06-16